EVO PT9

Manufacturer Pike Signals Limited
Specification TOPAS 2538A under review

More Info

Product Registered 14/2/17 Certificate 2017/0137

This product incorporates PT5

Previous HE Approved 2/12/15 for TR2502B, TR2537A, TR2538A

 

With exception to the points listed below

 

SA/SD equipment: (TR 2537A clause 2.58 & TR 2538A clause 2.57): This function is not included with this equipment

Cat 1 Failure Mode: (TR 2502B clause 2.60, TR 2537A clause 2.71 & TR 2538A clause 2.70): The system will go to all red heads for the max clearance time prior to signals off.

Vehicle to Pedestrian Intergreen: (TR 2537A clause 2.4): Controllers will run preceding vehicle all red time, prior to pedestrian green. A minimum of 3 second all red period will be achieved.

Pedestrian Green Time: (TR 2537A clause 2.42 & TR 2538A clause 2.39): The controllers offer alternative pedestrian green times, always with a minimum of 7 seconds

Automatic Comms Recovery: (TR 2537A clause 2.42 & TR 2538A clause 2.39) The controllers incprorat3e an automatic restart function, incorporating details as listed within PIKE signals technical note CRP/HA0306.

Please refer to technical document PIKE/EVO/PT5/0313 for clarification

Contact Details

The Apex, 2 Sheriffs Orchard, Coventry CV1 3PP
T: ##### ######
F: ##### ######
E: Email