EVO T2 Controller

Manufacturer Pike Signals Limited
Specification TOPAS 2538A under review

More Info

Registration 22/4/16   Registration Certificate Number 2016/0016

Previous HA Apprival 7.4.16 under TR2502B, TR2537A, TR2538A with the following exceptions:

 

This device may also function as a slave to specifications TR2537A & TR2538A
SA/SD Equipment (TR2537A clause 2.58 & TR 2538A clause 2.57): This function ins not included with this equipment
Cat 1 Failure mode: TR2502B clause 2.60, TR2537A clause 2.71 & TR2538A clause 2.70) The system will go to all red heads for the max clearnace time prior to signals off.
Vehicle to Pedestrian Intergreen (TR2537A clause 2.4) Controllers will run preceding vehicle all red time, prior to pedestrian green.  A minimum of 3 second all red period will be achieved.
Pedestrian Green Time: (TR2537A clause 2.42 & TR2528A caluse 2.39) The controllers offer alternative pedestrian green times, always with a minimum of 7 seconds.
Automatic Comms Recovery: (TR2537A clause 2.42 & TR2538A clause 2.39) The contollers incorporate an automatic restart function, incorporating details as listed within PIKE singals technical note CRP/HA0306.
Please refer to technical document PIKE/EVO/T5/0216 for clarification

 

 

 

 

Contact Details

The Apex, 2 Sheriffs Orchard, Coventry CV1 3PP
T: ##### ######
F: ##### ######