TOPAS Registration 6.2.15  Certificate : 2015/0021

Registered under HA Approval 3.6.13 in respect of TR2502B, TR2538A and TR2537A with the exception of the points listed below:

SA/SD  Equipment: (TR2537A clause 2.58 & TR2338A clause 2.57)  This function is not included with this equpment.

Cat 1 Failure mode: (TR2502B clause 2.60, TR2537A clause 2.71 and TR2538A clause 2.70): The system will go to all red heads for the max clearance time prior to signals off.

Vehicle to Pedestrian Intergreen: (TR2537A clause 2.4): Controllers will run preceding vehicle all red time, prior to pedestrian green.  A minimum of 3 second all red period will be achieved.

Pedestrian Green Time: (TR2537A clause 2.42 and TR2538A clause 2.39): The controllers offer alternative pedestrian green times, always with a minimum of 7 seconds.

Automatic Comms Recovery: (TR2537A clause 2.42 and TR2538A clause 2.39): The controllers incorporate an automatic restart functions, incorporating details as listed within PIKE signals technical note CRP/HA03036.